Auto Tuning hot runner controller , Multi zone Temperature Controller for Plastic Injection Machine
Characteristic
Short circuit, open circuit and system failure dual protection;
Segmentation heating and soft-start function
Pattern recognition,Plug and Play
Automatic or manual heating can be selectable
Degree C or F selectable
Thermocouple Type J standard, Type K selectable
Automatically compensates for ambient temperature
Over Temperature automatic protection
Automatic identification of load power ,Remarkable energy saving Heater and thermocouple dislocation identify the alarm function
With current detection function
Specifications
Input Voltage:AC110V / 220V
Load current:15A~18A
Rated Power:3600W(Peak power:4200W)
Operating Range:0~450℃
Temperature resolution:0.1℃
Control Accuracy: 0.1℃
Steady state:±0.5℃(Load disturbance is not big in the case)
Calibration Accuracy:Full scale 0.22%
Sampling process:250 times/s
Maximum adjustment cycle:2 minutes and 45 seconds
Short-circuit protection Response time<8 ms
Current consumption<100 mA
Demension
Type | 02A | 02B | 04A | 06A | 08A | 10A | 12A | 24A |
Zone | 1 ~ 2 | 1 ~ 2 | 3 ~ 4 | 5 ~ 6 | 7 ~ 8 | 9 ~ 10 | 11 ~ 12 | 13 ~ 24 |
Power Switch | 2P-40A×1 | None | 3P-63A×1 | 3P-63A×1 | 3P-63A×1 | 3P-63A×1 | 3P-63A×1 | 3P-63A×2 |
Power Supply | 1-Phase 3-wire AC220V | 1-Phase 3-wire AC220V | 3-Phase 5-wire AC380V | 3-Phase 5-wire AC380V | 3-Phase 5-wire AC380V | 3-Phase 5-wire AC380V | 3-Phase 5-wire AC380V | 3-Phase 5-wire AC380V |
Output Connector | 16PIN×1 or Cable | 16PIN×1 or Cable | 16PIN×1 | 24PIN×1 | 16PIN×2 | 24PIN×2 | 24PIN×2 | 24PIN×4 |
Dimension(mm) | L=185 H=200 D=290 | L=130 H=200 D=290 | L=310 H=210 D=290 | L=410 H=210 D=290 | L=510 H=210 D=290 | L=610 H=210 D=290 | L=710 H=210 D=290 | L=720 H=420 D=290 |
Protection Fuctions
1. Wide power supply range, AC85~415V
2. Thermocouple input protection, prevent module damaged by
mis-connection
3. Thermocouple & heater inverse protection, prevent
thermocouple damaged by mis-connection
4. Soft-start mode, avoid the humidity make the heater burn out
Diagnostic Function
Alarm when the followings occurred
1. Ultra-high or ultra-low Temperature
2. Thermocouple break, short or inverse
3. Thermocouple is out of its position
4. Heater break, short or overload
5. Output device is damaged
Accessories
Cables: provide 16/24 core combination hot runner cable and mold
power cable, thermocouple cable or customized
Wuhan Global Metal Engineering Co., Ltd
Wuhan Global Metal Engineering Co., Ltd (GME) specialize in the supply of heating elements and temperature sensors(thermocouples & RTDs) for a vast array of industries since year 1995.
Our main products include but not limited to Coil heater, Cartridge heater, Flexible Tubular heater, Cast-in Heater, Band heater, Thermocouple, RTD’s, Thermocouple extension wire, Thermocouple connection head , Mineral Insulated thermocouple cables , thermowell, etc.
After 20 years growth, we have more than 200 employees in the factory including 50 sophisticated technicians. Our products have been exported to many countries including North America, South America, Europe, Middle East ,South Asia, etc.
More details, you can also visit our website: https://www.gmemetal.com