Fireproof Sandwich Panels Clean Booth, Laminar Flow Down Booth
Introduction
The airflow in a modular cleanroom is a very important factor in the overall performance of the cleanroom. Most cleanrooms have an average air velocity of between 0.25-0.5 m/s. This is a relatively low air velocity, and therefore has the potential to be interrupted or disturbed by people and/or machinery within the cleanroom. On the other hand, raising the air speed too high will increase operational costs. When deciding upon the air speed to set within a cleanroom, an enterprise must first confirm that the selected air speed will be able to maintain an environment that meets cleanliness standards. However, the air speed required to meet these requirements should not be exceeded by too much, otherwise you will incur unnecessary costs.
Besides determining the appropriate air velocity, steps must be
taken to maintain a constant airflow and velocity. Otherwise, it is
possible for air to build up around the walls and form a sort of
vortex. If this occurs it is extremely difficult to cycle the air
in and out of the room, and thus nearly impossible to maintain a
clean environment.
In order for a laminar airflow cleanroom to maintain constant,
uniform airflow, all fans must be set to the same speed.
Additionally, if the air speed falls outside of the 0.25-0.5 m/s
range, it is also possible for vortex-like air patterns to occur in
the cleanroom.
Features:
(1) Assembly structure designed, easy installation and easily moved
(2) Directional wheels can be installed, suitable for small building and high cleanliness area;
(3) Modular design: clean booth can be as small as several square meters and can be as large as hundreds of square meters
(4) It has large useful and effective area; while compared with traditional clean room, it has such features like low investment, high return and stable.
Structure
Following options are available
1. Pass box
2. Air shower
3. ULPA filter
4. Sticky mats
5. Barometer
6. Gowning area
7. Pressure different control device
8. Transparent/grid PVC curtain
9. Thermo-static and humid-static air conditioning system.
When start the clean room
What information do you need to provide us for design the cleanbooth
1.What industry do you need the cleanbooth
2.What size and height and cleanliness do you need for cleanbooth?
3.What kind of work will be do in cleanbooth?
4.What kind of material for wall you want?
5.Do you have another special requirment?
Dimensions:
Class | Model | Dimension (WxDxH)mm *inner height | FFU Q'ty | Airflow (m3/h) |
Class 10-100 | MCR4X4 | 1220X1220X2150 | 2 | 2300 |
Class 10-100 | MCR4X8 | 1220X2440X2150 | 4 | 4600 |
Class 10-100 | MCR8X8 | 2440X2440X2150 | 8 | 9200 |
Class 10-100 | MCR8X12 | 2440X3660X2150 | 12 | 13800 |
Class 10-100 | MCR8X16 | 2440X4880X2150 | 16 | 18400 |
Class 10-100 | MCR8X20 | 2440X6100X2150 | 20 | 23000 |
Class 10-100 | MCR12X12 | 3660X3660X2150 | 18 | 20700 |
Class 1000 | MCR8X12 | 2440X3660X2150 | 9 | 10350 |
Class 1000 | MCR8X16 | 2440X4880X2150 | 12 | 13800 |
Class 1000 | MCR8X20 | 2440X6100X2150 | 15 | 17250 |
Class 1000 | MCR10X12 | 3050X3660X2150 | 8 | 9200 |
Class 1000 | MCR12X12 | 3660X3660X2150 | 10 | 11500 |
Class 1000 | MCR12X16 | 3660X4880X2150 | 12 | 13800 |
Class 1000 | MCR12X20 | 3660X6100X2150 | 16 | 18400 |
Class 10,000 | MCR8X8 | 2440X2440X2150 | 2 | 2300 |
Class 10,000 | MCR8X12 | 2440X3660X2150 | 2 | 2300 |
Class 10,000 | MCR8X16 | 2440X4880X2150 | 4 | 4600 |
Class 10,000 | MCR12X16 | 3660X4880X2150 | 5 | 5750 |
Other sizes as request.
Case display
KeLing Purification Technology Company
Keling Purification Technology Co., Ltd engaged in air purification field for many years, that is
Professional manufactory with research and development, produce, sales of air purification equipment and HVAC air filter.
our product concern the follow range:
1: Clean room equipment: clean room Air shower, Pass box,Duct HEPA filter box Dynamical pass thru, Laminar flow bench, fan filter unit, DOP air HEPA unit, Dispensing booth, sampling booth, laminar flow booth , soft wall clean room , air cleaner , laminar flow ceiling unit. Laminar flow wardrobe .
2: HVAC air filter: ULPA air filter, Mini-pleats HEPA filter, HEPA filter with clapboard filter, high
temperature-resistance filter, pocket air filter, V-cell air filter, pre-filter, active carbon air filter,
v-bank air filter with big air volume, bag air filter, panel air filter, z-line air filter and Grease filter.
3: Hard wall clean room project, such as design, construct and monitor service and raw material supply.
Our product service for biological, food, chemical, medicine, electronic, micro-electronics,
skin care, precise instrument industry and Aero-Space, laboratory, scientific, national defense area
and so on , Our product have good reputation in worldwide ,our client spread all over European
and Southeast Asia.
We have excellent technical team pursue the high quality to exist, insisted concept of credit for in sustainable development
We sincerely hope establish steady and friendly business relationship with you.
You will achieve what are you want!
Trust me! I will be your finally choose !